Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Esthet Restor Dent ; 36(2): 402-409, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37681984

RESUMO

OBJECTIVE: To evaluate the penetration of hydrogen peroxide (HP) into the pulp chamber and the color change of different bleaching varnishes in low concentrations used for at-home bleaching. MATERIALS AND METHODS: Ninety healthy premolars were used, randomly distributed into nine groups (n = 10) according to bleaching varnish (PL, PolaLuminate; VS, VivaStyle Paint On Plus; CA, Cavex Bite&White whitening pen and; AW AlignerWhite) and time (10 and 30 min), and a control group (no bleaching). The penetration of HP was evaluated by UV-Vis spectroscopy. To evaluate the color change (ΔEab , ΔE00 , ΔWID ) a digital spectrophotometer was used (α = 0.05). RESULTS: The AW group in 10 min and the control group showed similar and lower HP penetration in the pulp chamber when compared to the other groups (p = 0.003). Increasing the application time to 30 minutes elevated the amount of HP inside the pulp chamber for all groups (p = 0.003), except for PL (p > 0.05). When applied for 30 min all bleaching varnishes showed higher color change (ΔWID ) when compared to 10 min (p = 0.04). CONCLUSIONS: For all bleaching varnishes evaluated, PolaLuminate applied for 30 min showed lower penetration into the pulp chamber and higher bleaching effects. CLINICAL SIGNIFICANCE: The use of bleaching varnishes seems promising for teeth bleaching, but it varies according to user product and protocol.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio/farmacologia , Cavidade Pulpar , Clareamento Dental/métodos , Clareadores Dentários/farmacologia , Espectrofotometria , Cor
2.
J Esthet Restor Dent ; 36(3): 460-468, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37728145

RESUMO

OBJECTIVE: This study aims to assess hydrogen peroxide (HP) penetration into the pulp chamber, color change (CC), physical-chemical properties, and material wastage (MW) and material used (MU) in mixing tips when using in-office bleaching gels with two different mixing tips. MATERIALS AND METHODS: Forty teeth were divided into five groups (n = 8) based on the bleaching gels used (Pola Office +37.5% [PO+] and Whiteness HP Automixx Plus 35% [AM+]) and the mixing tip types (T-Mixer and Helical). A negative control group was treated with ultra-purified water. HP concentration was measured using UV-Vis, and CC was evaluated with a digital spectrophotometer. Initial concentration, pH, and viscosity were measured through Titration, a Digital pH meter, and Rheometer, respectively. MW and MU were measured using a precise analytical balance. Statistical analysis included two-way ANOVA, Tukey's, and Dunnett's test (α = 0.05). RESULTS: A higher HP concentration was observed with PO+ with the Helical mixing tip in comparison with AM+ (p = 0.01). No significant differences in CC or MU were found for different mixing tips (p = 0.001). The T-mixer mixing tip resulted in significantly less MW (p < 0.00001) and improved mixture homogeneity and viscosity. CONCLUSIONS: Utilizing a T-mixer with self-mixing bleaching gels achieves comparable CC while reducing MW. Moreover, it decreases HP penetration when using PO+. CLINICAL SIGNIFICANCE: For the application of a self-mixing in-office bleaching gel, a T-mixer mixing tip should be recommended, as it reduces the penetration of hydrogen peroxide into the pulp chamber when using PO+, while also minimizing gel wastage.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio , Clareamento Dental/métodos , Esmalte Dentário , Géis , Cor
3.
Restor Dent Endod ; 48(4): e33, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38053778

RESUMO

Objectives: This study aimed to evaluate the bleaching efficacy and hydrogen peroxide permeability in the pulp chamber by the at-home bleaching gel in protocols applied on different dental surfaces. Materials and Methods: Forty premolars were randomly into 4 groups: control group no bleaching, only application on the buccal surface (OB), only application on the lingual surface (OL) and application in buccal and lingual surfaces, simultaneously (BL). At-home bleaching gel (White Class 7.5%) was used for the procedure. The bleaching efficacy was evaluated with a digital spectrophotometer (color change in CIELAB [ΔE ab] and CIEDE 2000 [ΔE 00] systems and Whitening Index for Dentistry [ΔWID]). The hydrogen peroxide permeability in the pulp chamber (µg/mL) was assessed using UV-Vis spectrophotometry and data were analyzed for a 1-way analysis of variance and Tukey's test (α = 0.05). Results: All groups submitted to bleaching procedure showed bleaching efficacy when measured with ΔE ab and ΔE 00 (p > 0.05). Therefore, when analyzed by ΔWID, a higher bleaching efficacy were observed for the application on the groups OB and BL (p = 0.00003). Similar hydrogen peroxide permeability was found in the pulp chambers of the teeth undergoing different protocols (p > 0.05). Conclusions: The application of bleaching gel exclusively on the OB is sufficient to achieve bleaching efficacy, when compared to BL. Although the OL protocol demonstrated lower bleaching efficacy based on the ΔWID values, it may still be of interest and relevant in certain clinical scenarios based on individual needs, requiring clinical trials to better understand its specificities.

4.
Int J Dent ; 2023: 4625818, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37954498

RESUMO

Introduction: Dental bleaching is the first choice to improve smile esthetics, but, in some cases, it needs to be associated with resin composite restoration to obtain a satisfactory result. Unfortunately, the bonding of resin-based materials can be impaired due to residual oxygen molecules, which can decrease the durability of the restoration. Objectives: To evaluate the effect of the antioxidant application on the bond strength of bleached enamel after 24 hr and 3 years of water storage. Methods: In total, 84 bovine teeth were used in this study. Of these, 77 were bleached with 35% hydrogen peroxide in a single session for three cycles of 15 min. Then, the specimens were divided into groups (n = 7 each): control (without bleaching), without antioxidant (WA) use; application of 10% sodium ascorbate (SA) gel, grape seed (GS) extract, and aloe vera (AV). The restorative procedure was performed immediately after bleaching, 7 and 14 days after bleaching. Specimens were sectioned and evaluated using microtensile bond strength (µTBS). Half of the resin-enamel sticks were tested after 24 hr, and the remaining half after 3 years of water storage. µTBS data were analyzed using a three-way analysis of variance, Tukey's test, and Dunnett's test. Results: The lowest µTBS values were observed when the restoration was performed immediately after bleaching in the AV, GS, and WA groups when compared with the SA group (p < 0.005). However, no significant differences were observed among all groups after 3 years of water storage (p < 0.001). Conclusions: SA at 10% was the most effective antioxidant agent for improving the immediate bond strength. However, independent of the antioxidant agent used, the bond strength values were maintained or recovered after 3 years of water storage. SA at 10% could be used to avoid delayed bonding procedures after in-office whitening without compromising bond strength over time. Clinical Significance. The use of antioxidants after dental bleaching can be effective in improving the bonding durability of the adhesive restorations.

5.
Dent Mater ; 39(11): 1051-1057, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37793951

RESUMO

OBJECTIVE: To evaluate the effect of dimethyl sulfoxide (DMSO) on the microtensile bond strength (µTBS) and nanoleakage (NL) of universal adhesives on eroded dentine, immediately and after four years of water storage. METHODS: Sixty-four sound human molars were distributed into 16 groups according to (1) Dentine surface (sound and eroded dentine); (2) dimethyl sulfoxide application (with or without); (3) Application mode (etch-and-rinse or self-etch) and (4) Storage time (immediate and four years). One mild universal adhesive was used (Scotchbond Universal). The restoration was then performed with a composite resin and the specimens were sectioned into resin-dentine bonded sticks. Resin-dentine bonded sticks were tested (immediately and after four years of water storage) for µTBS (0.5 mm/min) or used to assess NL. Data on µTBS and NL were analyzed using four-way ANOVA and Tukey's test (α = 0.05). RESULTS: Only the 3-way cross-product interaction 'substrate vs DMSO vs time' was statistically significant (p = 0.007). Eroded dentine showed a lower mean of µTBS and a higher mean of NL values than sound dentine. However, when DMSO was applied, no significant decrease of µTBS or NL values was observed after four years of water storage, regardless of adhesive strategies, or dentine evaluated, when compared to immediate results. SIGNIFICANCE: Water-based DMSO pre-treatments not only prevent degradation of MDP-containing simplified adhesives but also serve as a potential alternative to improve long-term bonding properties to eroded dentine. The versatility of using a single pre-treatment for both self-etch or etch-and-rinse bonding to eroded dentin may facilitate future clinical applications.


Assuntos
Colagem Dentária , Dimetil Sulfóxido , Humanos , Cimentos Dentários , Colagem Dentária/métodos , Adesivos Dentinários/química , Condicionamento Ácido do Dente/métodos , Cimentos de Resina/química , Dentina , Água/química , Resistência à Tração , Teste de Materiais
6.
J Dent ; 136: 104633, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37490967

RESUMO

OBJECTIVES: To evaluate the microtensile bond strength (µTBS) and nanoleakage (NL) of several universal adhesives to eroded dentine (ED) using etch-and-rinse (ER) and self-etch (SE) strategies, immediately and after 6 years of water storage. MATERIAL AND METHODS: Four hundred and eighty human molars were distributed into 60 groups according to dentine substrate (sound dentine [SD], eroded with soft drink, or eroded with citric acid), application method of the adhesive (SE or ER), and the adhesives used: 1. All-Bond Universal, 2. Ambar Universal, 3. Clearfil Universal, 4. Futurabond U, 5. One Coat 7 Universal, 6. Peak Universal Bond, 7. Prime&Bond Elect, 8. Scotchbond Universal, 9. Tetric n-bond Universal, and 10. Xeno Select. The restoration was then performed with a composite resin, and the specimens were sectioned into resin-dentine bonded sticks. The sticks were tested (immediately or after 6 years of storage) for µTBS (0.5 mm/min) or used to assess NL. The eroded dentine surfaces were also examined using FE-SEM to evaluate the NL. Data for µTBS were analyzed by four-way ANOVA and Tukey's post-hoc test (a = 0.05), and the NL was analyzed by Kruskal-Wallis and the Wilcoxon Signed Rank Sum test (a = 0.05). RESULTS: In ED, there was no difference in µTBS and NL between ER and SE strategies (p > 0.05). Most µTBS and NL values obtained for ED were lower and higher, respectively, than those for SD (p < 0.005). Additionally, the worst results (µTBS and NL) were observed for erosion with citric acid groups in comparison with erosion with soft-drink groups (p < 0.007). After 6y, µTBS was generally lower and NL higher for all substrates, adhesives, and strategies (p < 0.05), except for AMB, SBU, and TEU in dentine eroded with citric acid. The lowest µTBS and highest NL values were observed for ABU, FBU, OCU, PUB, PBE, and XEN in both types of eroded dentine and evaluation times (p < 0.002). CONCLUSION: The use of MDP-containing adhesives seems to be essential to maintain adhesion to eroded dentine. However, other factors such as acidity should be considered. CLINICAL SIGNIFICANCE: The bonding of eroded dentine is a challenge. However, the use of MDP-containing universal adhesives showed less degradation after long-term evaluation.


Assuntos
Colagem Dentária , Cimentos Dentários , Humanos , Adesivos Dentinários/química , Colagem Dentária/métodos , Cimentos de Resina/química , Água/química , Dentina , Resistência à Tração , Teste de Materiais , Adesivos
7.
Clin Oral Investig ; 27(8): 4345-4359, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37217713

RESUMO

OBJECTIVE: The objective of the study is to evaluate through a randomized clinical trial the best method to preheat a composite resin, if using a Caps dispenser device associated with Caps Warmer (CD) or with a VisCalor Caps dispenser/warmer (VD) for restorations in non-carious cervical lesions (NCCLs). MATERIAL AND METHODS: One hundred and twenty restorations were distributed to two groups (n = 60) according to the pre-heating way of thermoviscous bulk-fill composite resin. For the CD group, pre-heating was carried at 68 °C using a heating bench for 3 min. For the VD group, pre-heating was performed at 68 °C using a heating gun for 30 s. After that, pre-heated bulk-fill composites were directly inserted in the NCCLs. The total working time was recorded. The restorations were evaluated after 6 and 12 months of clinical performance according to the FDI criteria. Statistical analysis was performed using the Student's t test for unpaired samples for working time, and the Chi-square test for restoration clinical performance (α = 0.05). RESULTS: Working time was shorter for VD with a statistically significant difference compared to CD (p = 0.01). Few restorations were lost or fractured after 12 months of clinical evaluation (p > 0.05). The retention rates were 96.7% (CI 95 %: 88.6-99.1%) for CD and 98.3% (CI 95 %: 91.1-99.7%) for VD. The other FDI parameters were considered clinically acceptable. CONCLUSIONS: The different pre-heating ways did not influence the clinical performance of thermoviscous bulk-fill composite restorations in NCCLs after 12 months. CLINICAL RELEVANCE: Regardless of the bulk-fill thermoviscous composite resin pre-heating ways, the restorations are clinically acceptable after 12 months.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Humanos , Restauração Dentária Permanente/métodos , Calefação , Resinas Compostas , Temperatura Alta , Adaptação Marginal Dentária
8.
Clin Oral Investig ; 26(6): 4381-4390, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35128627

RESUMO

OBJECTIVES: This split-mouth randomized, single-blind clinical trial evaluated the gingival irritation (GI) of at-home bleaching with individual trays of different cutouts, as well as the tooth sensitivity (TS) and color change. MATERIALS AND METHODS: One hundred and twenty patients were randomized as to which side would receive the type of bleaching tray cutout: scalloped (in the gingival margin) and nonscalloped (extended from the gingival margin). The at-home bleaching was performed for 30 min with 10% hydrogen peroxide (HP) for 2 weeks. The absolute risk and intensity of GI and TS were assessed with a visual analog scale. Color change was assessed using a digital spectrophotometer and a color guide (α = 0.05). RESULTS: The proportion of patients who experienced GI was 57.5% (odds ratio 95% CI = 1.1 [0.7 to 1.8]), with no significant difference between groups (p = 0.66). The proportion of patients who experienced TS was 64.1% (odds ratio 95% CI = 1.0 [0.6 to 1.6]), with no significant difference between groups (p = 1.0). There is equivalence of scalloped and noscalloped groups for GI intensity (p < 0.01). Significant whitening was detected for both groups. Although some differences were observed between groups (CIELab and CIEDE00; p < 0.02), these were below of the considered clinically noticeable. CONCLUSIONS: The different cutouts of trays proved to be equivalent when regarding gengival irritation and tooth sensitivity when 10% HP for at-home bleaching was used. Significant color change was observed in both groups. However, significant differences detected between groups are not considered clinically noticeable. TRIAL REGISTRATION: Brazilian Clinical Trials Registry (RBR-2s34685). CLINICAL RELEVANCE: Scalloped or not, the individual trays for at-home bleaching could be considered a clinician's decision.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Sensibilidade da Dentina/induzido quimicamente , Sensibilidade da Dentina/tratamento farmacológico , Humanos , Peróxido de Hidrogênio/efeitos adversos , Ácido Hipocloroso , Método Simples-Cego , Clareamento Dental/efeitos adversos , Clareadores Dentários/efeitos adversos , Resultado do Tratamento
9.
J Adhes Dent ; 21(4): 319-327, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31432046

RESUMO

PURPOSE: To evaluate the effect of different application modes of a recently introduced self-etching ceramic primer on the microshear bond strength (µSBS) and ceramic surface-etching pattern of two glass-ceramic surfaces. MATERIALS AND METHODS: Twenty-two CAD/CAM blocks of lithium disilicate (LD) and feldspathic glass ceramic (VTR) were each cut into 4 rectangular sections (n = 88 for ceramic surface). The LD and VTR specimens were divided into one control group (hydrofluoric acid + silane coupling agent [HF+SII]), and 10 experimental groups using Monobond Etch and Prime (MEP) applied for a combination of scrubbing times (5, 10, 20, 40, and 60 s) and reaction times (20 or 40 s). After each treatment, Tygon matrices (n = 8) were filled with a resin cement and light cured for each ceramic specimen. The specimens were stored in water at 37°C for 24 h and subjected to the µSBS test. The failure pattern and µSBS were statistically evaluated (α = 0.05). In addition, the ceramic surface etching pattern was analyzed using scanning electron microscopy. RESULTS: For the LD groups, the application of MEP 60/40 resulted in a higher mean µSBS compared to HF+SI (p < 0.05). Groups 5/40, 10/40, and 20/40 resulted in mean µSBS similar to that obtained by HF+SI (p > 0.05). For VTR, no significant difference was observed among the groups (p = 0.32). Compared with MEP, HF better promoted the dissolution of glass matrix for both ceramics. However, prolonged MEP scrubbing or reaction caused significant dissolution of the glass matrix for both evaluated ceramics. CONCLUSION: Active and prolonged application of MEP may be a viable alternative to HF+SI for increasing the bond strength to LD.


Assuntos
Colagem Dentária , Cerâmica , Porcelana Dentária , Ácido Fluorídrico , Teste de Materiais , Cimentos de Resina , Silanos , Propriedades de Superfície
10.
Braz Dent J ; 30(2): 171-178, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30970061

RESUMO

To evaluate the effect of combining 5% hydrofluoric acid (HF) and silane (SI) with the self-etching ceramic primer on the immediate and after 1-year of water storage on bonding efficacy, conditioning pattern (CP) and chemical interaction (CI) to the lithium disilicate. A total of 16 CAD/CAM blocks of lithium disilicate (LD) were cut into four square sections (n=64). For bonding efficacy evaluation, the LD specimens were divided into 4 groups (n=10): 1) HF+SI; 2) self-etching ceramic primer (MEP); 3) HF+MEP; 4) MEP+SI. After each treatment, an adhesive system was applied and Tygon matrices were filled with a dual-cured resin cement followed by light curing. Cylinder specimens (0.8 mmx0.5mm) were stored in water (37 °C for 24 h or 1-year) and submitted to the µSBS test (2-way ANOVA and Tukey's test; a=0.05). CP and CI were only evaluated qualitatively. No significant difference on the µSBS was observed between groups (p=0.73), but reduced µSBS was observed after 1-year of water storage (p>0.0001). After application of HF+SI and MEP, reduction in a number of siloxane bonds was observed, suggesting the coupling of SI on the LD surface. HF or HF+MEP produced a higher dissolution of the glassy matrix than the use of MEP alone. The MEP can be an alternative to traditional ceramic treatment once the chemical interaction and long-term bond strength were similar between both groups. The association of hydrofluoric acid or silane with a self-etching ceramic primer did not add any benefits in terms of chemical interaction and bonding stability.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Cerâmica , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Silanos , Propriedades de Superfície
11.
Braz. dent. j ; 30(2): 171-178, Mar.-Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001436

RESUMO

Abstract To evaluate the effect of combining 5% hydrofluoric acid (HF) and silane (SI) with the self-etching ceramic primer on the immediate and after 1-year of water storage on bonding efficacy, conditioning pattern (CP) and chemical interaction (CI) to the lithium disilicate. A total of 16 CAD/CAM blocks of lithium disilicate (LD) were cut into four square sections (n=64). For bonding efficacy evaluation, the LD specimens were divided into 4 groups (n=10): 1) HF+SI; 2) self-etching ceramic primer (MEP); 3) HF+MEP; 4) MEP+SI. After each treatment, an adhesive system was applied and Tygon matrices were filled with a dual-cured resin cement followed by light curing. Cylinder specimens (0.8 mmx0.5mm) were stored in water (37 °C for 24 h or 1-year) and submitted to the μSBS test (2-way ANOVA and Tukey's test; a=0.05). CP and CI were only evaluated qualitatively. No significant difference on the μSBS was observed between groups (p=0.73), but reduced μSBS was observed after 1-year of water storage (p>0.0001). After application of HF+SI and MEP, reduction in a number of siloxane bonds was observed, suggesting the coupling of SI on the LD surface. HF or HF+MEP produced a higher dissolution of the glassy matrix than the use of MEP alone. The MEP can be an alternative to traditional ceramic treatment once the chemical interaction and long-term bond strength were similar between both groups. The association of hydrofluoric acid or silane with a self-etching ceramic primer did not add any benefits in terms of chemical interaction and bonding stability.


Resumo Avaliar o efeito da combinação de ácido fluorídrico ou silano com o primer autocondicionante de cerâmicas sobre a eficácia da união imediata e após 1 ano de armazenamento em água, padrão de condicionamento e interação química desses tratamentos com o dissilicato de lítio. Um total de 16 blocos CAD/CAM de dissilicato de lítio (DL) foram cortados em quatro seções quadradas (n=64). Os espécimes de DL foram divididos em 4 grupos: 1) ácido fluorídrico a 5% + silano (HF + SI); 2) primer autocondicionante de cerâmica (MEP); 3) HF + MEP; 4) MPE + SI. Após cada tratamento, o sistema adesivo foi aplicado e as matrizes Tygon foram preenchidas com cimento resinoso dual (Variolink® II), seguido de fotopolimerização. Espécimes em forma de cilindro (0.8 mmÆ x 0.5 mm), foram armazenados em água (37 °C por 24h ou 1 ano) e submetidos ao teste μSBS (ANOVA dois fatores e teste de Tukey; a=0,05). Para avaliação das interações químicas por Espectroscopia Raman, os espécimes de DL foram divididos em 3 grupos (n=4): 1) sem tratamento (DL); 2) HF + SI; e 3) MEP. Para avaliação do padrão de condicionamento da superfície cerâmica após os tratamentos por MEV, os espécimes de DL foram divididos em 3 grupos (n=3): 1) DL; 2) HF; 3) MEP; e 4) HF + MEP. Ambos os métodos foram avaliados apenas qualitativamente. Não foi observada diferença significativa na μSBS imediata entre os grupos (p=0,73), mas após 1 ano de armazenamento das amostras em água, reduziu μSBS (p>0,0001). HF ou HF + MEP produziram uma maior dissolução da matriz vítrea do que o uso de MEP sozinho. Após a aplicação de SI e MEP, observou-se redução de ligações de siloxano, sugerindo o acoplamento da camada de silano na superfície do DL. O primer autocondicionante cerâmico pode ser uma alternativa ao tratamento cerâmico tradicional, uma vez que a interação química e a resistência de união a longo prazo, quando comparada ao tratamento tradicional foram estatisticamente semelhantes. A associação de ácido fluorídrico ou agente de acoplamento silano com um primer autocondicionante de cerâmicas não agregou nenhum benefício em termos de interação química e estabilidade.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Silanos , Propriedades de Superfície , Teste de Materiais , Cerâmica , Cimentos de Resina , Porcelana Dentária , Análise do Estresse Dentário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...